{"product_id":"gamewell-fci-gfp-a","title":"Gamewell-FCI GFP-A Elevate Intelligent Fire Alarm Control Panel, Grey","description":"\u003cp\u003eThe \u003cstrong\u003eGamewell-FCI GFP-A\u003c\/strong\u003e is part of the Gamewell-FCI Elevate™ fire alarm platform. Intelligent addressable fire alarm control panel for small to mid-size facilities with a 10\" touchscreen, one SLM-318 loop (318 devices) expandable to two, 4 NACs and a 6.0 A universal-input power supply in a grey enclosure.\u003c\/p\u003e\n\u003cp\u003eIntelligent fire alarm control panel with a grey enclosure. Includes one signaling loop module (318 devices), a 10inch touchscreen display, 4 NACs, a universal AC input power supply, and an enclosure.Expandable to 2 loops with one additional SLM-318\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10\" high definition touchscreen display with customizable buttons\u003c\/li\u003e\n\u003cli\u003e6.0 A power supply with customizable outputs\u003c\/li\u003e\n\u003cli\u003eFour Class A\/B power outputs configurable as NACs, power, door holder or Universal Zone Coding (UZC licensable)\u003c\/li\u003e\n\u003cli\u003eNACs support selectable System Sensor, Wheelock and Gentex strobe synchronization\u003c\/li\u003e\n\u003cli\u003eEasy expansion of isolated intelligent SLC capacity - one expandable to two\u003c\/li\u003e\n\u003cli\u003eUp to 159 detectors and 159 modules per SLC; 318 devices per loop \/ 636 per FACP\u003c\/li\u003e\n\u003cli\u003eSupports Honeywell patented Self-Test detectors and magnet-activated AV testing\u003c\/li\u003e\n\u003cli\u003eWireless fire protection using SWIFT Smart Wireless Integrated Fire Technology\u003c\/li\u003e\n\u003cli\u003eCompatible with existing SLC wiring for Velociti and CLIP devices from Gamewell-FCI S3 Series installations\u003c\/li\u003e\n\u003cli\u003eAdvanced smoke control management with appliance- and zone-based configuration\u003c\/li\u003e\n\u003cli\u003eWeekly Occupancy Schedules allow changing sensitivity by time of day and day of week\u003c\/li\u003e\n\u003cli\u003eHistory buffer 10,000 events (3000 displayed) with advanced history filters\u003c\/li\u003e\n\u003cli\u003eAlarm Verification selection per point, with automatic counter\u003c\/li\u003e\n\u003cli\u003eUp to 2000 Boolean logic equations\u003c\/li\u003e\n\u003cli\u003eIntegrates with Connected Life Safety Services (CLSS) via CLSS Gateway for remote programming, testing and diagnostics\u003c\/li\u003e\n\u003cli\u003eField programmable with CAMWorks+ Tools\u003c\/li\u003e\n\u003cli\u003eCertified for seismic applications when used with the appropriate seismic mounting kit\u003c\/li\u003e\n\u003cli\u003eFuture networking capability through firmware upgrade\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGFP-A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eGamewell-FCI Elevate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling Line Circuits (SLC)\u003c\/td\u003e\n\u003ctd\u003e1 expandable to 2 (one additional SLM-318)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevices per SLC (Velociti)\u003c\/td\u003e\n\u003ctd\u003e159 detectors and 159 modules; 318 devices per loop \/ 636 per FACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e10\" high definition touchscreen with customizable buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e6.0 A with customizable outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNAC \/ power outputs\u003c\/td\u003e\n\u003ctd\u003eFour Class A\/B power outputs configurable as NACs, power circuit, door holder circuit or Universal Zone Coding circuit (UZC licensable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary outputs\u003c\/td\u003e\n\u003ctd\u003eTwo, configurable resettable or non-resettable (Class B and Class A\/B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrobe synchronization\u003c\/td\u003e\n\u003ctd\u003eSelectable System Sensor, Wheelock and Gentex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary input power (PMB)\u003c\/td\u003e\n\u003ctd\u003e120VAC 50\/60 Hz 2.5A, 240VAC 50\/60 Hz, 1.25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24VDC aux output 1\u003c\/td\u003e\n\u003ctd\u003e24VDC, 2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24VDC aux output 2\u003c\/td\u003e\n\u003ctd\u003e24VDC, 2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPU current draw\u003c\/td\u003e\n\u003ctd\u003e0.116 A (Standby), 0.116 A (Alarm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain display current draw\u003c\/td\u003e\n\u003ctd\u003e0.153 A (Standby), 0.163 A (Alarm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charger range\u003c\/td\u003e\n\u003ctd\u003e7AH-100AH. Use separate cabinet for batteries over 26 AH.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging current\u003c\/td\u003e\n\u003ctd\u003e1A, 2A, 4.25A, and 5.55A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloat rate\u003c\/td\u003e\n\u003ctd\u003e27.6 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries in enclosure\u003c\/td\u003e\n\u003ctd\u003e26AH batteries can be accommodated inside the enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHistory buffer\u003c\/td\u003e\n\u003ctd\u003e10,000 events, 3000 displayed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic equations\u003c\/td\u003e\n\u003ctd\u003eUp to 2000 Boolean logic equations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinter port\u003c\/td\u003e\n\u003ctd\u003eSupplemental EIA-232 printer port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIO bus\u003c\/td\u003e\n\u003ctd\u003eExternal AIO Bus supports Class A (200ft on 16AWG) or Class B (6000ft at 16AWG); internal AIO bus Class B (6000ft at 16AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote displays\u003c\/td\u003e\n\u003ctd\u003eUp to 10 GFP-RLDs per GFP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSWIFT wireless\u003c\/td\u003e\n\u003ctd\u003eEach SWIFT Gateway supports up to 49 devices; up to 4 wireless gateways\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReleasing\u003c\/td\u003e\n\u003ctd\u003eUp to 50 agent releasing zones and up to 100 water releasing zones (licensed, multiples of 10); releasing using TC810S1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOut-of-box capabilities\u003c\/td\u003e\n\u003ctd\u003eUp to 2 loops, 1 PMB, 250 General Zones, 250 Logic Zones, 8 Custom Action Buttons, 2 Smoke Control Zones, 20 Smoke Control Appliances, 20 FSAE devices, 11 Virtual Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming\u003c\/td\u003e\n\u003ctd\u003eCAMWorks+ (Version 7.20 or higher); Autoprogram; optional remote programming through CLSS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eDual telephone line to central station using Ademco Contact ID with optional DS dialer; CLSS Gateway connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e35 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackbox dimensions\u003c\/td\u003e\n\u003ctd\u003e19.12\" H x 18.12\" W x 5.47\" D (48.6 cm h x 46 cm W x 13.9 cm D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature and humidity\u003c\/td\u003e\n\u003ctd\u003eOperation 0-49°C\/32-120°F; relative humidity 93% ± 2% RH (non-condensing) at 32°C ± 2°C (90°F ± 3°F); recommended room temperature 15-27°C\/60-80°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003ctd\u003eS1949\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFM Approved\u003c\/td\u003e\n\u003ctd\u003eFM26US0098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSFM\u003c\/td\u003e\n\u003ctd\u003e7165-1703:0512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFDNY\u003c\/td\u003e\n\u003ctd\u003eApproved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeismic\u003c\/td\u003e\n\u003ctd\u003eCertified for Seismic applications in accordance with IBC 2024: VMA-45894-02C (with appropriate seismic mounting kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOSHPD\u003c\/td\u003e\n\u003ctd\u003eApproved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eUL 864 10th edition; UL 2017; install per NFPA 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL type service\u003c\/td\u003e\n\u003ctd\u003eLocal, Releasing, Auxiliary (requires TM-8), Remote Station (requires TM-8), Proprietary, Central Station, Emergency Signaling (require HON-CGW-MB or HON-DACT-DS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eBackbox 19.12\" H x 18.12\" W x 5.47\" D (48.6 x 46 x 13.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e35 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and documents\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes:\u003c\/strong\u003e Enclosure, SLM-318 signaling loop module (1), PMB power supply (4 NACs, 2 aux outputs), 10\" touchscreen display\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWorks with:\u003c\/strong\u003e SLM-318, TM-8, GFP-RLD, ACM-30, ACM-30W, LDM2-32, LDM2-60, DIS-10-RD, SEISKIT-GFP-A, HON-CGW-MB \/ HON-CGW-MBB (CLSS Gateway), HON-DACT-DS, HPF-PS6\/10 power supplies, BAT Series batteries, BB-100, PRN-7, GFP-* panel licenses\u003c\/p\u003e\n\u003cp\u003eGFP-A = grey enclosure (official SKU text and datasheet say Grey, not black). GFP-AR = identical panel in red enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/prod-edam.honeywell.com\/content\/dam\/honeywell-edam\/hbt\/en-us\/documents\/literature-and-specs\/datasheets\/hon-ba-fire-9021-2192-b-gfp-a-gfp-ar-datasheet-8-13.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload the datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLead time:\u003c\/strong\u003e typically ships in 2–3 weeks.\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":68069167104213,"sku":"GFP-A","price":1849.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/5826\/3253\/files\/hon-ba-fire-gfp-a-front.jpg?v=1793538554","url":"https:\/\/fireservicesgroup.com\/products\/gamewell-fci-gfp-a","provider":"FSG - Fire Services Group","version":"1.0","type":"link"}