System Sensor 4W-B i3 series 4-wire 12/24 VDC detector with base
System Sensor 4W-B i3 series 4-wire 12/24 VDC detector with base - view 2
System Sensor 4W-B i3 series 4-wire 12/24 VDC detector with base - view 3
System Sensor 4W-B i3 series 4-wire 12/24 VDC detector with base - view 4
System Sensor 4W-B i3 series 4-wire 12/24 VDC detector with base - view 5
System Sensor 4W-B i3 series 4-wire 12/24 VDC detector with base
System Sensor 4W-B i3 series 4-wire 12/24 VDC detector with base - view 2
System Sensor 4W-B i3 series 4-wire 12/24 VDC detector with base - view 3
System Sensor 4W-B i3 series 4-wire 12/24 VDC detector with base - view 4
System Sensor 4W-B i3 series 4-wire 12/24 VDC detector with base - view 5
System Sensor 4W-B i3 series 4-wire 12/24 VDC detector with base
System Sensor 4W-B i3 series 4-wire 12/24 VDC detector with base - view 2
System Sensor 4W-B i3 series 4-wire 12/24 VDC detector with base - view 3
System Sensor 4W-B i3 series 4-wire 12/24 VDC detector with base - view 4
System Sensor 4W-B i3 series 4-wire 12/24 VDC detector with base - view 5

System Sensor 4W-B i3 Series 4-Wire Detector with Base, 12/24 VDC

The System Sensor 4W-B is a conventional four-wire i3 series photoelectric smoke detector, supplied as a plug-in head with its base. It is powered from a separate supervised power circuit and signals alarm through dry contacts, a common arrangement on security or combination panels that provide auxiliary power.

SKU: 4W-B

In stock – ships within 1 business day
Need a project quantity? Request a quote →

Free 30-Day Returns

Hassle-free returns

1-Year Warranty

Manufacturer warranty

Product details

The System Sensor 4W-B is a conventional four-wire i3 series photoelectric smoke detector, supplied as a plug-in head with its base. It is powered from a separate supervised power circuit and signals alarm through dry contacts, a common arrangement on security or combination panels that provide auxiliary power.

Key features

  • Photoelectric-only model with no thermal element
  • Alarm reported by a contact closure, independent of the power circuit
  • Low alarm draw: 20 mA at 12 V, 23 mA at 24 V
  • Pre-wire the base at rough-in, then fit the head with Stop-Drop 'N Lock
  • Drift compensation, smoothing algorithms and dual-color status LEDs

Installation notes

Supervise the detector power run, normally with an end-of-line relay, so a loss of power shows as a trouble at the panel. The 4W-B has no freeze trouble function; that belongs to the thermal models.

Also searched as: 4WB

Specifications

Model 4W-B (i3 series)
Wiring 4-wire, non-polarized
Operating voltage 12/24 V nominal (8.5 V min, 35 V max)
Standby current 50 µA average max
Alarm current 20 mA at 12 V; 23 mA at 24 V
Alarm contacts 0.5 A at 30 V AC/DC
Nominal sensitivity 2.5%/ft
Operating temperature 32°F to 120°F (0°C to 49°C)
Dimensions with base 5.3" diameter x 2.0" (51 mm) high
Weight 6.3 oz (178 g)
Mounting 3-1/2" or 4" octagonal, single-gang, or 4" square box with plaster ring; or direct to ceiling
Listing UL 268